Views: 0 Author: Site Editor Publish Time: 2023-02-17 Origin: Site
6 common faults of deep well pump
1. Pumping is not allowed or the head is seriously insufficient: at this time, the water pump will not turn
when it is running, and the submersible pump will also have large noise when it is idling. Most of these
phenomena are caused by the damage of the bearings of the submersible pump.
2. Poor sealing: the shaft extension end of the water pump motor has a double-end mechanical seal
component, which is made of high wear-resistant materials. After the submersible pump has been used for a
period of time, the seal element causes poor sealing due to wear or natural aging, resulting in oil leakage
and water seepage. In addition, there are circular rubber sealing rings on each mechanical mating surface to form
a sealing pad to prevent water from seeping into the pump body. However, due to the high motor speed of submersible
pump application, the mechanical seal end face will be seriously worn in long-term application.
3. The water outlet pipe is damaged and leaking: the sound of normal rotation of the submersible pump impeller suspended
in the deep well can be heard (the electric meter also rotates normally), but the water can not be pumped or only a small
amount of water can come up. Most of these conditions are that the water outlet pipe has been damaged.
4. Pump jamming: the pump does not rotate, but the buzzing noise can be heard. Most of this is because the pump impeller is stuck
by foreign matters. For example, due to geological reasons, the sand content of well water is high, which is easy to damage the filter screen cover.
5. Leakage: leakage is one of the common faults of the submersible pump. The common fault phenomenon is that when the
switch is closed, the leakage protector in the distribution room will automatically trip, which is also caused by the leakage of water
in the pump body of the submersible pump.
6. The starting capacitor fails: the buzzing sound can be heard when the power is connected, but the submersible pump
motor does not rotate; At this time, if the impeller is gently moved and the submersible pump can rotate immediately, it can be judged
that the capacitor has been damaged.